The median ring size was 32 mm (range 26-40 mm) On-table trans-o

The median ring size was 32 mm (range 26-40 mm). On-table trans-oesophageal echocardiography (TOE) showed trivial/no MR in 87 patients, and mild in 13 patients, and there were no cases

of systolic anterior motion (SAM). There were two re-explorations for bleeding and two patients required haemofiltration. There were no strokes or deep sternal wound infections (DSWIs). There was one hospital death (1%). At discharge, mean left AZD4547 inhibitor ventricular end-diastolic (LVEDD) was 4.8 +/- 0.7 cm compared with 5.5 +/- 0.8 cm preoperatively (p = 0.03) and mean left ventricular endsystolic (LVESD) was 3.3 +/- 0.5 cm as compared with 3.6 +/- 0.8 preoperatively (p = 0.4). There was no MR in 87 patients and mild MR in 13 patients. The mean mitral valve area (MVA) was 2.8 +/- 0.7 cm(2). The mean systolic pulmonary artery pressure (SPAP) was 26.6 +/- 7.3 mmHg as compared with 50.9 +/- 17.2

mmHg preoperatively (p = 0.02). During follow-up, there were no thrombo-embolic complications, re-operation, endocarditis or deaths. Conclusions: MV repair with the Physio II ring has excellent short-term results, including subgroups with large anterior mitral AZD6094 manufacturer valve leaflet (AMVL). Moreover, the dimensional ratios of the ring may allow it to be used for MV repair for degenerative MV disease, irrespective of anterior leaflet size. Crown Copyright (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.”
“Purpose: Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare buy BLZ945 gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF. Methods: Eighty-nine patients with diagnosed HF who underwent both gated F-18 FDG PET/CT and cardiac MRI within 3 days were included in the analysis. Left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), and EF were obtained from gated F-18 FDG PET/CT using the Quantitative Gated SPECT (QGS) and 4D-MSPECT

software. Results: LV EDV and LV ESV measured by QGS were significantly lower than those measured by cardiac MRI (both P smaller than 0.0001). In contrast, the corresponding values for LV EDV for 4D-MSPECT were comparable, and LV ESV was underestimated with borderline significance compared with cardiac MRI (P = 0.047). LV EF measured by QGS and cardiac MRI showed no significant differences, whereas the corresponding values for 4D-MSPECT were lower than for cardiac MRI (P smaller than 0.0001). The correlations of LV EDV, LV ESV, and LV EF between gated F-18 FDG PET/CT and cardiac MRI were excellent for both QGS (r = 0.92, 0.92, and 0.76, respectively) and 4D-MSPECT (r = 0.93, 0.94, and 0.75, respectively). However, Bland-Altman analysis revealed a significant systemic error, where LV EDV (-27.9 +/- 37.

Comments are closed.