The pooled inter-plate %GCV across assays was between 1 6 and 3 4

The pooled inter-plate %GCV across assays was between 1.6 and 3.4% depending on the nature of the sample and between 1.9 and 3.7% across samples, depending on the assay. Between assay variation was assessed by calculating the GCV, expressed as a percentage of the overall mean potency per sample over the 3 assays (%GCV), and varied between 2.2 and 6.7% depending on the sample. The variation between duplicate samples within a plate and within an assay is assessed by calculating the root mean square expressed as a percentage of the mean relative potency for each sample (RMS%). selleck chemical There was excellent agreement between duplicates of the positive control antibody; and also between

the duplicates of an antibody positive sample after calculation of the mean relative potencies over the 3 assays. The within plate variability as represented by the average % difference between duplicated sample for the 3 plates per assay is low (1.0 to 4.7%, depending on the sample and the assay). The low pooled inter-assay %GCV (4.3%) together with the low values for the inter-plate %GCV showed a very good reproducibility between plates within an assay and a very good reproducibility

of the bridging assay over time. Binding of ruthenium-conjugated IFN-β (diluted in PBS or pooled normal human sera) to two available forms of IFN-β receptors was evaluated in AZD4547 presence or absence of neutralizing antibody positive control 99/606. The receptors used were a human recombinant IFN-α/β R2/Fc chimera and the viral protein B18R, a type I IFN receptor encoded by the B18R gene of the Western Reserve vaccinia virus strain. As expected, the complexity of the interferon receptor present on mammalian cells, comprising Fluorometholone Acetate two subunits, is not mimicked by immobilizing the IFN-α/β R2 alone. Conversely the

B18R protein is sufficient for IFN-β to stably bind to the cell surface (Colamonici et al., 1995 and Alcami et al., 2000) and was therefore used in subsequent NAb assays. The assay was optimized by immobilizing increasing concentrations of B18R and of the tested concentrations the highest signal was observed when 0.4 μg/ml B18R was immobilized. In agreement with the challenge concentrations usually employed in NAb assays (Wadhwa and Thorpe, 2008), 20 ng/ml of ruthenium-conjugated IFN-β was used as a challenge concentration as its response corresponds to 75% of the maximum signal observed when increasing concentrations of ruthenium-conjugated IFN-β were allowed to bind to immobilized B18R, as shown in Fig. 2. We found that standard bare plates allow for a higher signal to noise ratio at all concentrations of immobilized receptor in comparison with high bind plates and were therefore used in subsequent studies. Statistical analysis was based on the potencies relative to the positive control 99/606 after fitting a 4-parameter dose–response-curve to the data.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>